Brand Name : SADT
Model Number : SC100A
Certification : ISO9001, CE, SGS
Place of Origin : Made in China
MOQ : 1pc
Price : Negotiation
Payment Terms : T/T, Western Union, Paypal
Supply Ability : 5000 pcs /year
Delivery Time : 3 days upon advanced payment
Packaging Details : rigid carrying case
Illumination / observa-tion system : d/8(Diffused lighting, 8 degrees observe angle), SCI(specular reflection included)/SCE(specularreflection excluded)simultaneous measurement, (conforms to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards)
Illumination Lightsource : CLEDs(entire wavelength balanced LED light source
Sphere Size : Φ40mm, diffused reflection surface coating
Sensor : dual light path sensor array
Wavelength range : 400nm-700nm
Wavelength interval : 10nm
Half spectral width : 5nm
Reflecttivity range : 0 to 200%
Observation angle : 2°/ 10°degrees
Measurement light source : A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF
Displayed data : SPD distribution/data, sample’s color values, color difference values/graph, pass/fail results, colorerror tendency, color simulation, display measurement area, history data color simulation, manual input standard sample, generate measurement report
Measurement time : 1 second
Measurement time interval : 2 seconds
Test Aperture : 10mm 4mm/6mm(Optional
Color space : CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance
Color difference formulas : ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00
Other colorimetric indices : WI(ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925, ASTM E313-00, ASTM E313-73), Tint(ASTM E313, CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness
Repeatability : light splitting reflectivity, standard deviation within 0.08% color values;ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals), Maximum: 0.05
Battery capacity : rechargeable, 10000 continuous tests, 7.4V/6000mAh
Interface : USB
Data storage : 20000 test results
Light source life : 5 years, 1.5 million tests
Inter-instrument agree-ment : ΔE*ab within 0.2(BCRA color charts II, average of the 12 charts)
Dimension : 181*73*112mm(L*W*H)
Weight : about 550g(does not include battery’s weight)
Display : True color screen that includes all colors
Work environment : 0°C~45°C, relative humidity 80% or below( at 35°C ),no condensation
Storageenvironment : -25°C- 55°C,relative humidity 80% or below(at 35°C ),no condensation
Spectrophotometer SC 100A
SC100ASpectrophotometeradopts inter-nationally agreed observe condition D/8 (Diffused lighting, 8 degrees observe angle)and SCI(specular reflection included)/
SCE(specular reflection excluded). It could be usedfor color matching for many industries and widelyused in painting industry, textile industry, plasticindustry, food industry, building material industryand other industries for quality control.
KEY FEATURES
In previous measurement instrument, we can only aim at thetesting area approximately, and this may introduce errors.Our spectrophotometers include a camera in our opticalsystem, and the user can clearly see the tested area to avoid measurement errors.
LED light source that has balanced intensity across visiblespectrum avoids the spectral deficiency in certain parts of the spectrum in common white LEDs, and guarantees the speed of the measurement and the accuracy of the results.This research finding has been published in national leading, SCI included optical journal, Chinese Optics Letter.
Currently, most instruments use standard white boards forcalibration. When white board is damaged, the instrument’saccuracy or precision will no longer be guaranteed. In CHN-Spec’s spectrophotometers, we adopt innovative ETC(EveryTest Calibration); standard white board is included in theoptical system, and therefore has reliable accuracy and re-peatability in every measurement.
Our spectrophotometer comes with PC color QC software,which is applicable in various industries for management ofcolor data. It is used for store test result, generate test reportand print test report after connect with printer.
Gloss will greatly affect the measurement of color. Our in-strument adopts automatic gloss compensation technologywhich guarantees the accuracy of color measurement value for surfaces of different gloss.
Adopt innovative single-grating-dual-light-paths light splitting system:SCS optical engine which creates the best measurement repeatability forportable spectrophotometers and guarantees accurate measurement ofsurface color of materials.Low battery prompt function, full data spaceprompt function.
Comparing with similar products, our spectrophotometers offer the most complete, 28kinds of standard light sources and 40 measurement color value indicators; It can alsocustomize measurement methods according to your requirement, and satisfy all your colormeasurement needs.
Standard package
SC100A main unit 1
Standard white tabula 1
Standard black cavity 1
USB cable 1
Software CD 1
Power adapter 1
Operation manual 1
Carrying case 1
Optional accessory
Micro Printer
Specifications
Model | SC 100A |
Illumination / observa-tion system | d/8(Diffused lighting, 8 degrees observe angle), SCI(specular reflection included)/SCE(specularreflection excluded)simultaneous measurement, (conforms to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Illumination Lightsource | CLEDs(entire wavelength balanced LED light source) |
Sphere Size | Φ40mm, diffused reflection surface coating |
Sensor | dual light path sensor array |
Wavelength range | 400nm-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflecttivity range | 0 to 200% |
Reflecttivity resolution | 0.01% |
Observation angle | 2°/ 10°degrees |
Measurement light source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF |
Displayed data | SPD distribution/data, sample’s color values, color difference values/graph, pass/fail results, colorerror tendency, color simulation, display measurement area, history data color simulation, manual input standard sample, generate measurement report |
Measurement time | 1 second |
Measurement time interval | 2 seconds |
Test Aperture | 10mm 4mm/6mm(Optional) |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance |
Color difference formulas | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00 |
Other colorimetric indices | WI(ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925, ASTM E313-00, ASTM E313-73), Tint(ASTM E313, CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness |
Repeatability | light splitting reflectivity, standard deviation within 0.08% color values;ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals), Maximum: 0.05 |
Battery capacity | rechargeable, 10000 continuous tests, 7.4V/6000mAh |
Interface | USB |
Data storage | 20000 test results |
Light source life | 5 years, 1.5 million tests |
Inter-instrument agree-ment | ΔE*ab within 0.2(BCRA color charts II, average of the 12 charts) |
Dimension | 181*73*112mm(L*W*H) |
Dimension | 181*73*112mm(L*W*H) |
Weight | about 550g(does not include battery’s weight) |
Display | True color screen that includes all colors |
Work environment | 0°C~45°C, relative humidity 80% or below( at 35°C ),no condensation |
Storageenvironment | -25°C- 55°C,relative humidity 80% or below(at 35°C ),no condensation |
![]() |